Skip to main content

The --where expression language

--where takes an expression that is evaluated as an event-level existence cut: the event passes if any row of the driver bank makes the expression truthy. The same grammar powers scan --expr computed columns and the TUI's live / filter.

It is available on count, scan, dump, skim, sample, and tui.

hipoq count rec.hipo --where "REC::Particle.pid == 11 && REC::Particle.chi2pid < 3"
Leading minus

Because a value can start with - (e.g. -1 < px < 1), the parser accepts it — your shell won't mistake the expression for a flag. Always quote the whole expression.

How an expression is evaluated

An expression is a numeric function of one bank row. For each row of the driver bank, hipoq evaluates the expression to a f64 and asks whether it is truthy:

a value is truthy when it is non-zero and not NaN.

  • Comparisons (==, <, …) and logic (&&, ||, !) evaluate to 1.0 (true) or 0.0 (false).
  • Any other expression is truthy on its own terms — --where "charge" keeps rows whose charge is non-zero (positive or negative), and --where "px*px + py*py - 0.25" keeps rows where that quantity isn't exactly zero. You'll almost always write a comparison, but the language doesn't require one.

The event passes when any driver row is truthy. (An expression with no per-row column references — a pure count(...)/constant like count(REC::Particle) >= 2 — is evaluated once for the event.)

References

FormMeaning
BANK.columnthat column, e.g. REC::Particle.px
column (bare)binds to the driver bank, e.g. px
column[N]element N of a fixed-length array column, e.g. cov[0]
count(BANK)number of rows in BANK (a multiplicity)
count(expr)number of rows where expr holds
any(expr)1 if any row of expr's bank satisfies it (unlinked)
all(expr)1 if every row satisfies it (and there is ≥1 row)
number11, -0.5, 1.5e-2
particlee-, pi+, proton, … — the PID it stands for (see below)

Column references may name any scalar numeric column — every integer type (byte/short/int/long) and float type (float/double) is read as a number.

Array columns

A fixed-length array column (declared cov/F#6 — six floats per row) is cut on one element at a time, chosen with a subscript:

hipoq count rec.hipo --where "REC::Track.cov[0] > 1e-4"
hipoq count rec.hipo --where "REC::Track.cov[0] > REC::Track.cov[5]"

The index is 0-based and checked against the schema when the expression is compiled, so cov[9] on a six-element column fails before any file is read:

column REC::Track.cov has 6 elements, so the index must be 0..5; got [9]

Naming an array without a subscript is refused rather than guessed:

column REC::Track.cov is an array (length 6); pick an element, e.g. `cov[0]`

That is deliberate. "Any element", "every element" and "element 0" are three different cuts and nothing in cov > 1 says which was meant — so it asks. A subscript on a scalar is refused for the mirror reason.

What it costs

An element read is about 16 % slower than a scalar one — 10.2 vs 12.2 Mev/s on a 200 000-event fixture with three rows per event, single-threaded. The library exposes a whole scalar column in one call but an array column one row at a time, so an element costs a column lookup per row where a scalar costs one per event. --explain says which references pay it.

To see every element of a row at once, use dump (arrays come out as real JSON arrays), scan, or press v in the TUI.

Particle names

Anywhere a PID number is expected you can write the particle instead — the same names --topology takes and --pdg prints:

hipoq count rec.hipo --where "REC::Particle.pid == e-"
hipoq count rec.hipo --where "REC::Particle.pid in (e-, pi+, pi-, proton)"

e- e+ mu- mu+ gamma pi+ pi- pi0 K+ K- p pbar n d t he3 he4 alpha and the spelled-out forms (electron, positron, photon, proton, neutron, deuteron, triton) all resolve. Nuclei use CLAS12's Geant3 codes (45/46/47/49), matching what is in the file.

Two rules keep this from changing what any existing expression means:

  • A real column always wins. The name is read as a particle only when the driver bank has no column of that name, so a bank that genuinely has a gamma or n column keeps reading the column.
  • Qualified references are never particles. REC::Particle.n is always the column n — naming a bank says a column is meant.

One consequence worth knowing: a charge sign binds to the name when it follows immediately, so e- is the electron while e - 1 (spaced) is a subtraction. Ordinary columns are unaffected — px-1 still subtracts, because px- is not a particle name.

p and e are rejected on purpose

These two name a particle and a physics helper, so hipoq refuses to guess:

$ hipoq count rec.hipo --where "p > 1000"
`p` is ambiguous: write `p()` for the physics quantity, or `2212` for the particle

The reason is the silent failure on the other side. p() > 1000 is false for a 2 GeV track; if a dropped () quietly meant the proton PID, p > 1000 would be 2212 > 1000 — true for every event, with no error. Write p() or proton (e() or e-) and both readings stay available.

Operators

Precedence, high to low: unary · * / % · + - · comparison · && · ||. Parenthesize with ( … ).

GroupOperators
arithmetic+ - * / % and unary -
comparison== != < <= > >=
logical not!x1 when x is falsy, else 0
range (chained)lo < x < hi is lo < x && x < hi (any comparison operators)
membershipx in (a, b, c) is x==a || x==b || x==c
logic&& ||

% is the floating-point remainder, and / is floating-point division (there is no integer division — 7 / 2 is 3.5).

hipoq count rec.hipo --where "-5 < REC::Particle.chi2pid < 5" # range
hipoq count rec.hipo --where "REC::Particle.pid in (11, 211, -211, 2212)" # membership

Functions

Unary: sqrt abs sin cos tan asin acos atan log exp floor ceil round sign deg rad pdg_mass.

Binary: atan2 pow min max hypot.

Notes:

  • Trigonometric functions work in radians; deg / rad convert radians ↔ degrees (deg(atan2(py, px)) for an azimuth in degrees).
  • log is the natural logarithm (base e); exp is its inverse.
  • sign(x) is -1, 0, or +1.
  • pdg_mass(pid) returns the PDG rest mass in GeV for a particle id. The bundled table covers the common CLAS12 species (leptons, photon, π/K/η/ω, p/n and hyperons, light nuclei); an unknown id yields NaN (which then makes any comparison false).
  • Calling a function with the wrong number of arguments is an error.
hipoq count rec.hipo --where "sqrt(px*px + py*py + pz*pz) > 1.5" # bare cols, driver = REC::Particle

Physics helpers

Zero-argument helpers that expand to bare-column arithmetic on the driver bank — so they read the driver's px / py / pz (and pid, for energy). They follow CLAS12 REC::Particle conventions and are meant for that bank (or a scan of it); used where those columns don't exist they raise the usual unknown-column error.

HelperExpands to
p()sqrt(px*px + py*py + pz*pz)
pt()sqrt(px*px + py*py)
theta() / theta_deg()polar angle acos(pz / p) (radians / degrees)
phi() / phi_deg()azimuth atan2(py, px) (radians / degrees)
e() / energy()energy sqrt(p² + pdg_mass(pid)²)
hipoq count rec.hipo --where "REC::Particle.pid==11 && p() > 1.5 && theta_deg() < 20"

Because e() uses pdg_mass(pid), a row whose pid is not in the PDG table gets a NaN energy. These are the same expressions behind the scan presets.

Inclusive kinematics: Q2 and W

Unlike the helpers above, these are per event, not per row: they read one specific particle and give the same value for every row of the event.

HelperMeaning
Q2(beam_energy)Q² = 2·E·E′·(1 − cos θ), the negative four-momentum transfer squared
W(beam_energy, target_mass)W = √(M² + 2M(E − E′) − Q²), the invariant mass of the hadronic system

Both take the beam energy in GeV, because nothing in the file reliably carries it. W needs it as well as the target mass — the energy transfer ν = E − E′ and Q² both depend on the beam — so W(0.938272) is an error rather than a guess:

hipoq count rec.hipo --where "Q2(10.6) > 1.0 && W(10.6, 0.938272) > 2.0"
hipoq scan rec.hipo --bank REC::Particle --expr "q2=Q2(10.6)" --expr "w=W(10.6, 0.938272)"

The trigger electron

Both read REC::Particle row 0, and only if it is an electron (pid == 11) with a negative status — the CLAS12 convention marking the particle that fired the trigger.

Anything else gives NaN: row 0 is a different particle, its status is positive, or the event has no REC::Particle at all. That is deliberate. A Q² computed off a pion looks entirely plausible and there is nothing downstream that could catch it, so the helpers decline rather than guess.

NaN compares as false, so --where "Q2(10.6) > 1" drops the events without a trigger electron instead of counting them. If you want to know how many those are, count them directly:

hipoq count rec.hipo --where "REC::Particle.pid == 11 && REC::Particle.status < 0"
The electron mass is neglected

E′ is taken as |p⃗|, the standard CLAS12 form. At 10.6 GeV the m_e² term is ~2.6 × 10⁻⁷ GeV², a part in 10⁷ of a typical Q².

Below pion threshold a badly reconstructed track can make negative; W is NaN there rather than an imaginary number rendered as a float.

The beam energy and target mass must be constants — they describe the run, not a row, and a column there would make the value per-row again, which is the one thing these are not.

Aggregates (multiplicity)

count(...) turns a per-row condition into an event-level number — the basis of multiplicity cuts:

hipoq count rec.hipo --where "count(REC::Particle.pid==11) >= 2" # ≥2 electrons
hipoq count rec.hipo --where "count(REC::Particle)==2 && count(REC::Calorimeter)>=3"
  • count(BANK) — total rows in the bank (0 if the bank is absent).
  • count(expr) — rows where expr is true, evaluated over expr's own driver bank (see unlinked aggregates).
A bare column is not a valid aggregate argument

count(REC::Calorimeter) is the row count, but count(REC::Calorimeter.energy) would follow the count(expr) rule and count rows whose energy is non-zero — one dot apart, a silently different number. On a bank with three rows and pindex = 0, 0, 1, the two readings give 3 and 1.

So hipoq refuses it rather than picking one:

$ hipoq count rec.hipo --where "count(REC::Calorimeter.energy) > 2"
count(REC::Calorimeter.energy) counts rows where `energy` is non-zero, which is rarely what is meant.
Instead, for the number of rows write count(REC::Calorimeter); to count non-zero
values write count(REC::Calorimeter.energy != 0)

The same applies to any(...) and all(...). Writing the comparison you mean (!= 0, > 0.1, …) always works.

CLAS12-native cross-bank evaluation

An expression runs over the rows of a driver bank, chosen like this:

  1. the first referenced bank with no pindex column (so REC::Particle drives when present);
  2. if every referenced bank has a pindex, the first referenced bank;
  3. if the expression is only bare columns, REC::Particle (when the file has it) — otherwise hipoq asks you to qualify a column as BANK.column.

Same-bank references use the current row, so pid==11 && charge<0 means one particle that is both. A reference to another bank is resolved by the CLAS12 pindex link, and the direction is set by whether the driver has a pindex:

  • sum — driver is the primary (REC::Particle, no pindex): a detector column is summed over the rows whose pindex points at the current particle;
  • gather — driver is a detector bank (has pindex): a REC::Particle column is read for the particle this row points at;
  • broadcast — a single-row bank with no pindex (e.g. REC::Event) applies to every driver row. (Two same-length banks align row-for-row.)
# electron whose OWN total calorimeter energy exceeds 1.5 GeV (same particle)
hipoq count rec.hipo --where "REC::Particle.pid==11 && REC::Calorimeter.energy > 1.5"

# electrons in positive-helicity events (broadcast)
hipoq count rec.hipo --where "REC::Particle.pid==11 && REC::Event.helicity > 0"

Checking which join you got: --explain

Sum, gather and broadcast give materially different answers from the same text, and the choice follows from which banks carry a pindex — not from anything visible in the expression. --explain prints the compiled plan and exits without reading any events, so a cut can be checked before a scan is spent on it:

hipoq count rec.hipo --where "REC::Particle.pid==11 && REC::Calorimeter.energy>0.5" --explain
--where "REC::Particle.pid==11 && REC::Calorimeter.energy>0.5"
driver bank: REC::Particle
REC::Particle.pid: read directly
REC::Calorimeter.energy: summed over rows whose pindex points at the driver row

--explain is a global flag, so it applies anywhere: on the commands that take --where (count, scan, dump, skim, sample, tui), and on any command at all when it is --topology you want explained — stats, hist and quality included. It reports each aggregate's own driver bank. Given nothing to explain it says so and exits 2:

$ hipoq info run.hipo --explain
--explain: this command has no --where or --topology to explain

Unlinked aggregates: any() / all()

Sometimes you want to ask about banks independently — "the event has an electron and (any) calorimeter hit above 1.5 GeV", not tied to the same particle. Wrap each bank in any(...) (or count(...)): each aggregate is self-contained, with its own driver bank, so no pindex join happens between them.

# unlinked: an electron somewhere AND a high-energy calo hit somewhere
hipoq count rec.hipo --where "any(REC::Particle.pid==11) && any(REC::Calorimeter.energy>1.5)"

Contrast the two forms:

FormQuestion
pid==11 && REC::Calorimeter.energy>1.5is there an electron whose own (pindex-summed) calorimeter energy > 1.5?
any(pid==11) && any(REC::Calorimeter.energy>1.5)is there an electron and, separately, any calorimeter hit > 1.5?
  • any(expr) is exactly count(expr) > 0.
  • all(expr) is true when every row satisfies expr and there is at least one row (an empty or absent bank makes all(...) false).

Multiple --where clauses

--where is repeatable, and the clauses are ANDed. But each clause is compiled independently and keeps its own driver bank — which is not the same as joining them with && inside one expression when they reference different banks:

# TWO clauses — unlinked: some electron exists AND some calo hit > 1.5 exists
hipoq count rec.hipo --where "REC::Particle.pid==11" --where "REC::Calorimeter.energy>1.5"

# ONE expression — linked: an electron whose OWN summed calo energy > 1.5
hipoq count rec.hipo --where "REC::Particle.pid==11 && REC::Calorimeter.energy>1.5"

So separate --where flags behave like wrapping each in any(...); && within a single expression links the banks by pindex on a shared driver row. Reach for separate clauses when the conditions target different banks and you don't want them tied together.

Numeric semantics

  • Float tolerance. Comparisons are tolerant at ~f32 precision: two numbers count as equal when

    |a - b| <= 1e-6 * max(|a|, |b|, 1)

    This is why px == 0.1 matches a value stored as 0.1_f32. The tolerance applies to every comparison, not just ==: < and > are strict-but-tolerant (a value within tolerance of the bound is treated as equal, so it does not satisfy a strict <), while <= and >= are inclusive of it. Integer columns differ by at least 1, far above the tolerance, so integer comparisons like pid == 11 stay exact.

  • Big integers. A long column compared against a whole-number literal is compared in 64-bit integers, not floats. Above 253 (9007199254740992) a f64 cannot represent every i64 — 10000000000000000 and 10000000000000001 share one — so a run number or timestamp up there would otherwise match two neighbouring values at once. Arithmetic on such a column (timestamp / 2) still goes through f64 and can lose the last digits; compare the column directly if that matters.

  • NaN. A NaN operand makes a comparison false, and a bare NaN is not truthy. Domain errors produce NaN (acos of an out-of-range argument, log of a negative), and divide-by-zero produces ±Inf.

  • Computed columns. In scan --expr, a row that evaluates to NaN or Inf is rendered as a null/empty cell rather than aborting the scan.

Errors

The language fails loudly rather than silently matching nothing — a broken cut is a hard error, reported before any event is read:

  • an unknown bank or column (bank "REC::Partical" … typo);
  • an array column used without an element, an out-of-range element, or a subscript on a scalar — see Array columns;
  • an unknown function or the wrong argument count;